ambient-air intake and hot-air exhaust must not be short-circulated. A piece of
wood may be used to separate them.
Cut a rectangular inside opening at the rear of the cabinet with the 1/4”
clearance inwards to the width and height of the cooling unit. By not going
through, leave 1/2” lip inside at the wall to place the gaskets (see Fig. 2.1 &
2.2).
If top exhaust installation, cut another rectangular opening at the top of the
cabinet to the length and width of the top exhaust (see Fig. 2.1 & 2.3).
Install 2 pieces of 1/4” ID wood thread inserts at the ceiling (see Fig. 2.1 &
2.4).
Place the gaskets (1/2” foam tape) on the gasket lips (see Fig. 2.1 & 2.5).
If top exhaust installation, place another gaskets along the top exhaust at the
top of the cooling unit (see Fig. 2.1 & 2.6).
Move the cooling unit towards the mounting sides and push to press the
gaskets.
Use 2 mounting brackets and ¼” screws with 7/16” wrench to secure the
cooling unit (see Fig. 2.7).
Install the front cover using two #8 screws on each side (see Fig. 2.8).
Install the wall grille at the back of the cabinet (see Fig. 2.11).
Plug the cooling unit in the cabinet receptacle.
Plug the wine cabinet.